DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-718FL-DATA (Flash Data Consistency)
10
FL-DATA (Flash Data Consistency)
In systems with high or critical reliability, the software and the hard patch update
files are stored in the on-board flash memory in both the Active SPE and Standby
SPE. The translations and announcements are stored in the memory cards in
both the Active SPE and Standby SPE. Flash Data Consistency flags problems
when files become mismatched by monitoring the translations, announcements,
update files, and software vintage number in a High or Critical Reliability PPN
system. If the software vintage numbers on both SPEs are mismatched, a
MAJOR alarm is raised. If the announcement files on bot h memory cards are
mismatched, a WARNING alarm is raised. For all other problems, a MINOR alarm
is raised. The software vintage can be displayed via the list configuration
software-vintage long command. The Flash Data Consistency Test is run on
system technician command and as part of daily Standby SPE maintenan ce.
NOTE:
Flash Data Consistency is not applicable to Standard systems.
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log) Alarm
Level Initial Command
to Run Full Name of MO
FL-DATA MAJOR test card-mem a|b l Flash Data Consistency
FL-DATA MINOR test card-mem a|b l Flash Data Consistency
FL-DATA WARNING test card-mem a|b l Flash Data Consistency
Table 10-204. Flash Data Consistency Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
010 Any Any Any test card-mem a/b l
8 or 16 8 or 16 Flash Data Consistency
Test (#421) WNG OFF test card-mem a/b
1-3,
9-10,
17-18,
32-34,
40-42,
Continued on next page