DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page8-13busyout journal-printer
8
Output
For the following output example, assume that the command that was entered is
"busyout data-module 300."
Feature Intera c tions
None.
busyout journal-printer
This command will busyout a maintenance object associated with the system
technician specified pms-log or wakeup-log.
Synopsis
busyout journal-printer [ pms-log | wakeup-log ]
Port The port address (cabinet-carrier-slot-circuit) of the maintenance
object that is being busied out, or the number of the data
channel.
Maintenance Name The type of maintenance object that is being busied o ut.
Alt. Name The alternate means of identifying the maintenance object. Thi s
field contains the extension when the object is a station, and it
contains xxx/yyy when the object is a trunk, where xxx is the trunk
group number and yyy is the member number. It contains P/xxx
when the object is a private CO line, where xxx is the private CO
line group number.
Result An indicator as to whether the object was successfully busied
out.
Error Code A numerical description of why the command failed.
busyout data-module 300 SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C1103 DIG-LINE 300 PASS
Command successfully completed