DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page8-48cancel hardware-group
8
Output
For the following output example, assume that the command that was entered is
"busyout trunk 78/1."
Feature Intera c tions
None.
cancel hardware-gro u p
This command allows a user to cancel an active "test hardware-group" command
executing in the background or foreground mode.
Synopsis
cancel hardware-group
Port The port address (cabinet-carrier-slot-circuit) of the maintenance
object that is being busied out.
Maintenance Name The type of maintenance object that is being busied o ut.
Alt. Name The alternate means of identifying the maintenance object. Thi s
field contains the extension when the object is a station, and it
contains xxx/yyy when the object is a trunk, where xxx is the trunk
group number and yyy is the member number. It contains P/xxx
when the object is a private CO line, where xxx is the private CO
line group number.
Result The result of the busyout - "PASS", "ABORT", "FAIL".
Error Code A system-generated number that tells why the busyout failed or
aborted. A detailed list of the codes can be found i n the
"Busyout/Release Error Codes" section of this chapter.
busyout trunk 78/1 SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C1505 CO-TRK 78/01 PASS
Command successfully completed