DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-1168PR-MEM (TN790 RISC Memory)
10
Notes:
a. Refer to PROCR (TN790 RISC Processor) Maintenance documentation for
a description of these tests.
b. This test is run only on the Standby SPE in a High or Critical Reliability
system. On other systems or on the Active SPE, the test is run only via a
reset system 4 command or a reset system 5 command.
c. Refer to PR-MAINT (MainTenance Processor) Maintenance
documentation for a description of these tests.
Read All Memory Test (#85)
This test is a nondestructive test. The test reads every mem ory location in
memory. A failure of this test indicates a DRAM failure in the Processor
circuit pack. DRAM is replaceable and installed in 3 Single Inline Memory
Module (SIMM) sockets on this circuit pack. Replacement of these SIMMs
is described in the "Circuit Pack Replacement Procedure" section.
Table 10-352. TEST #85 Read All Memory Test
Error Code Test
Result Description/ Recommendation
100 ABORT The r equested test did not complete within the allowable time period.
1. Retry the command.
1029 2014
2015 2016
2017 2018
2020 2022
2024 2025
2051
ABORT Refer to STBY-SPE Maintenance documentation for a description of
these error codes.
2500 ABORT I nternal system error
1. Retry the command.
Continued on next page