DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-306CO-BD (Central Office Trunk Circuit Pack)
10
CO-BD (Central Office Trunk Circuit
Pack)
Refer to XXX-BD (Common Port Circuit Pack) Maintenance documentation for
circuit pack level errors. See also CO-TRK (CO Trunk) Maintenance
documentation for related trunk information.
1. Where P is the port network number (1 for PPN an d 2 or 3 f or EPN) ; C i s the car rier des ignation (f or
example, A, B, C, D, or E); and SS is the address of the slot in the carrier where the circuit pack is
located (for example, 01, 02, ..., etc.).
MO Name As
It Appears in
Alarm Log Alarm
Level
Initial System
Technician
Command to Run1Full Name of MO
CO-BD MIN test board PCSS sh Central Office Trunk Circuit Pack
CO-BD WRN test board PCSS sh Central Office Trunk Circuit Pack