DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-408DATA-CHL (Network Control Data Channel)
10
Table 10-112. TEST #111 Data Channel Local Loop Back Test
Error
Code Test
Result Description/Recommendation
4 ABORT For this test, an Error Code of 4 can have one of two different meanings:
a. The target DATA-CHL is busy and, therefore, not available for use.
b. Internal system error
Determine if the target DATA-CHL is in use for some other function (that is,
CDR Link, System Printer Link, Journal Printer Link, PMS Link , or seco ndary
administration terminal connection) as described previously in t he "Status
of network Control Data Channels" section. If so, check for errors on the
function that is using the DATA-CHL. If there are no errors, there is a high
probability that the DATA-CHL is not defective. Proce ed with the remaining
steps only if it is necessary to completely test the target DATA-CHL.
1. If the target DATA-CHL is in use for some other function, busyout the
function (PRI-CDR/SEC-CDR, SYS-PRNT, PMS-PRNT/JNL-PRNT,
PMS-LINK) or the DATA-CHL (secondary administration terminal
connection only).
2. Retry the command at 1-minute intervals a maximum of 5 tim es.
3. Restore any busied out PRI-CDR/SEC-CDR, SYS-PRNT,
PMS-PRNT/JNL-PRNT, PMS-LINK MOs to service before moving on to
another activity.
40
70
75
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 tim es.
Continued on next page