DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page8-650test shadow-link
8
Output
The responses will be displayed on a test-by-test basis with one line of data
displayed for each test result.
For the following output example, assume that the command that was entered
was "test processor a".
Feature Intera c tions
None.
test shadow-link
This command allows the technician to test the shadow link.
Port The port address (cabinet-carrier) of the maintenance object that
is being tested.
Maintenance Name The type of maintenance object that is being tested is M EMORY.
Alt. Name Not applicable.
Test No. The actual test that is being executed.
Result The result of the individual test -"PASS," "ABORT," "FAIL," "NO
BOARD," "DISABLED," "EXTRA BD".
Error Code A system-generated number that tells why the release failed or
aborted. A detailed list of the codes according to "Test No." is
provided for each MO.
test processor a SPE B
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01A PROCR 77 PASS
01A PROCR 80 PASS
01A PROCR 82 PASS
01A PR-MAINT 102 ABORT 1018
01A PR-MAINT 103 ABORT 1018
01A PR-MAINT 106 PASS
01A PR-MAINT 228 PASS
01A PR-MAINT 229 ABORT 1018
01A MEMORY 87 PASS
01A MEMORY 631 PASS
Command successfully completed