DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-627E-DIG-STA (Emulated Digital Line)
10
E-DIG-STA (Emulated Digital Line)
There are 4 tests in the Emulated Digital Line station maintenance test sequence
and only one test path in the test sequence. Once the test sequence is started,
all tests in the test sequence are executed.
E-DIG-ST maintenance monitors and tests ports on the TN800 MAPD circuit pack
and the hardware connected to those ports for lines administ ered as a digital
station. These include stations with an emulated digital voice terminal and
stations with an emulated digital voice terminal and a linked data module.
Stand-alone data modules and data adaptors in stand-alone mode are not
supported by the TN800 circuit pack. Circuit pack maintenance is covered by
E-DIG-BD.

Hardware Error Log Entries and

Test to Clear Values

1. Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier
designation (for example, A, B, C, or D); and SS is the address of the slot in the carrier
where the circuit pack is located (for example, 01, 02,...).
MO Name (in
Alarm Log) Alarm Level Initia l C o mmand to
Run1Full Name of MO
E-DIG-STA MINOR test port PCSSpp l Emulated Digital St.
E-DIG-STA WARNING test port PCSSpp sh Emulated Digital St.
Table 10-180. Digita l Line Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
010 Any Any Any test port PCSSpp sh r 1
18 (a) 0 busyout port PCSSpp WNG OFF rel port PCSSpp
130 (b) None WNG ON test port PCSSpp sh
1793 (c) Voice and Control Local
Loop Test (#13) MIN/
WNG2ON test port PCSSpp l r 3
2049 (d) NPE Crosstalk Test (#9) MIN/
WNG2ON test port PCSSpp l r 3
2305 (e) 32770 None
Continued on next page