DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-499DIOD-DS1 (DS1 DIOD Trunk)
10
Three trunk service states are specified by DS1 DIOD trunk maintena nce:
Hardware Error Log Entries and Test to Clear
Values
out-of-service The trunk is in a deactivated state and
cannot be used for either incoming or
outgoing calls.
in-service The trunk is in an activated state and can
be used for both incoming and outgoing
calls.
disconnect (ready-for-service) The trunk is in an activated state but can
only be used for an incoming call.
DS1 DIOD Trunk Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
010 Any Any Any test trunk <grp>/<mbr>
1(a) 57408
1(a) 57487
57476
57477
57485
15(b) Any Port Audit and
Update Test (#36)
18(c) 0 busyout trunk
<grp>/<mbr> WARNIN
GOFF release trunk
<grp>/<mbr>
130(d) None WARNIN
GON test trunk <gr p>/<mbr>
257(e) 57392 DS1 CO Dial Tone
Seizure Test (#314) MIN/MAJ2OFF
513(f) 57393 DS1 Tie Trunk
Seizure Test (#136) MIN/MAJ2OFF
769(g) 57484
1025(h) 51200
1025 DS 1 CO Dial Tone
Seizure Test (#314) MIN/
WRN3OFF test trunk <grp>/<mbr>
r 2
Continued on next page