DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-1183PROCR (Processor Circuit Pack)
10
Error Log Entries and Test to Clear Values
Notes:
a. The Software Initiated Interrupt Test (#77) failed. Refer to the FAIL
condition of this test for further action.
b. The ROM Checksum Test (#80) failed. Refer to the FAIL condition of this
test for further action.
c. The Processor Non-maskable Interrupt Test (#82) failed. Refer to the FAIL
condition of this test for further action.
d. The Processor Sanity Timer Test (#83) failed. Refer to the FAIL condition of
this test for further action.
1. Software does not accept the repeat option on the TN773 circuit pack [G3iV1.1-286]. The r epeat
option is valid only on the TN786B circuit pack. You must manually repeat the command with the
long option the designated number of times from the admini stration t erminal and from a rem ote SAT
because the Sanity Timer Test (#83) logs you off. In G3iV1. 1-286, i f the t est process or long Sys tem
Technician command is executed six times back-to-back, the system goes int o SPE-DOWN mode.
2. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 10-361. 80286/386 Processor Circuit Pack Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value1
020 Any Any Any test processor a/b r 1
1 (a) 0 Software Initiated
Interrupt Test (#77) MAJOR ON test processor a/b r 3
769 (b) 0 ROM Checksum Test
(#80) MAJOR ON test processor a/b r 5
1025 (c) 0 Processor
Non-maskable
Interrupt Test (#82)
MAJOR ON test processor a/b r 2
1281 (d) 0 Processor Sanity
Timer Test (#83) MAJOR ON test processor a/b l r 2