DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page8-137display synchro nization
8
If the port location is not administered, the following message is displayed:
Identifier not assigned
If the specified port location is out of range, the following message is displayed:
Port/Board location invalid
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
Command resources busy; Press CANCEL to clear, and then resubmit
Output
For the following output example the command "display port 1c0801" was
entered.
Feature Intera c tions
None
display synchronization
This command displays the system synchronization administration such as
stratum level (3,4), primary and secondary synchronization reference sources
and DS1 boards.
Port: The port address (cabinet-carrier-slot-circuit) of the specified user
specified port.
Equipment Type: The hardware that is physically connected to the user specified port.
Identification: This depends on the hardware that is physically conne cted to the
port. If a station is connected to the port the station extension is
displayed, if a trunk is connected to the port a trunk group and
member is displayed, If a modem pool is connected to the port, the
modem pool group is displayed, etc.
display port 1c0801 SPE A
PORT INFORMATION
Port: 01C0801
Equipment Type: Station
Identification: 1021