DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-838ISDN-TRK (DS1 ISDN Trunk)
10
There are two methods available to place an outgoing ISDN-PRI test call in
G3iV1.1-286 and G3iV2-386.
In the first method, the test call connection is established over the TDM Bus of
the transmit and receive sides of the ISDN-PRI trunk to a data channel. This
method is selected when no Maintenance/Test circuit pack resides in the system.
In the second method, the test call connection is estab lished over the TDM Bus
of the transmit and receive sides of the ISDN-PRI trunk to a d igital trunk testing
port on the Maintenance/Test circuit pack. The Maintenance/Test Digital Port
generates a pseudo bit stream. A pictorial description of the outgoing ISDN-PRI
test call connectivity is contained in the following figure.
Figure 10-61. ISDN-PRI Outgoing Test Call
Synchronous Commands
You can demand a synchronous outgoing test call by using the following
maintenance commands:
test trunk trunk-group-no/member - no l ong [r epe at nu m be r ]
test board board-location long [repeat number]
test port port-location long [repeat number]
PI (TN765)
or
PACCON
(TN778)
NETCON SPE
D-channel Setup
B-channel
B-channel
TDM BUS
M/T
TN7771B
DS1/UDS1