DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-1004PDMODULE, TDMODULE (Data Module)
10
Hardware Error Log Entries and Test to Clear
Values
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
2. G3iV1.1-286 and G3iV2-386 only.
PDMODULE and TDMODULE Error Log En t ries
Error
Type Aux
Data Associated Test Alarm Level On/Off
Board Test to Clear Value
010 Any Any Any test port PCSSpp sh r 1
1 (a) 40987 None WARNING OFF
1 (b) 1 to 20 None WARNING OFF
15 (c) Any None
18 (d) 0 busyout port
PCSSpp WARNING OFF release port PCSSpp
257 (e) 40971 None
51320 Data Module Audits
Test (#17) WARNING
(j) OFF test port PCS Spp sh r 6
769 (f) 40988 None WARNING OFF
1281 Any Data Module Audits
Test (#17) WARNING OFF t e st po rt PCSSpp sh r 4
1537 (g) 40968 None WARNING OFF
1793 Information
Channel and
Control Channel
Loop Around Test
(#13)
MINOR ON test port PCSSpp l r 3
2049 NPE Crosstalk Test
(#9) MINOR ON test port PCSSpp l r 3
2305 (h) 32770 None
2305 (i) 40967 None
2561 Data Module
Internal Loop
Around Test (#175)
WARNING OFF t e st po rt PCSSpp l r 5
2817 (k) Link GPP Loop
(183) Against Links MAJOR ON
3841 (l) NONE