DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-308CO-DS1 (DS1 CO Trunk)
10
Hardware Error Log Entries and Test to Clear
Values
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test
description and follow the recommended procedures.
2. This alarm will only be raised when the System-Parameter Country form has the Base Tone Genera tor field set
to 4 (Italy). This alar m will be a MINOR alar m unless 75% or more trunks in this trunk g roup are out of servic e,
then the alarm will be upgraded to a MAJOR alarm.
DS1CO Trunk Error Log Entri e s
Error Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
010 Any Any Any test trunk
<grp>/<mbr>
1 (a) 57408
1 (a) 57487
15 (b) Any Port Audit and
Update Test (#36)
18 (c) 0 busyout trunk
<grp>/<mbr> WARNING OFF release trunk
<grp>/<mbr>
130 (d) None WARNING ON test trunk
<grp>/<mbr>
257 (e) 57392 DS1 CO Dial Tone
Seizure Test (#314) MIN/MAJ2OFF
513 (f) 57393 DS1 CO Dial Tone
Seizure Test (#314) MIN/MAJ2OFF
769 (g) 57484
1025 DS1CO Dial Tone
Seizure Test (#314) WARNING OFF test trunk
<grp>/<mbr>
1281 Conference Circuit
Test (#7) MAJ/MIN/
WRN3ON test trunk
<grp>/<mbr> r 4
1537 NPE Crosstalk Test
(#6) MAJ/MIN/
WRN3ON test trunk
<grp>/<mbr> r 3
1793 (h) ON test board PCSS l
2562(i)) 16665
2817(j) 52992
3840 (k) Port Audit and
Update Test (#36)