DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-643ERR-LOG (Error Log)
10
ERR-LOG (Error Log)

Functional Description

The ERR-LOG MO is responsible for the sanity of the Alarm Log, the Hardware
Error Log, and the Software Error Log. If an inconsistency is detected in any on e
of these logs, all logs are re-initialized and a hardware error is logged against
ERR-LOG indicating the time of inconsistency. There are no tests and no alarms
for the Error Log MO. This MO exists solely for the purpose of allowing errors to
be logged against it.

Hardware Error Log Entries and Test to Clear

Values
Notes:
a. This error indicates that an inconsistency was detected in either the Alarm
Log, the Hardware Error Log, or the Software Error Log. To recover from
this error, all of the logs were cleared and re-initialized. Any alarms that
were active at the time of this error have been cleared. There is no
associated test for this error. If the error persists, escalate the problem.
The Aux data value indicates when the inconsistency was f ound:
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to
the appropriate test description and follow the recommended procedures.
MO Name As It
Appears in
Alarm Log Alarm Level
Initial System
Technician
Command to Run Full Name of MO
ERR-LOG none none Error Log
Error Log Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01Any Any Any Any none
510 (a) Any none none none none
0 Found during a periodic audit of the Error Log
1 Found after an ext ended reboot
Continued on next page