Maintenance Object Repair Procedures
Page10-1670XXX-BD (Common Port Circuit Pack)
10
Hardware Error Log Entries and Test to Clear
Values
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
2. G3iV1-1.286 or G3iV2-386 only
Common Port Circuit Pack M aintenance Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
010 Any Any Any test board PCSS sh r 1
1(a) 0 Circuit pack
removed or SAKI
Sanity Test (#53)
MINOR ON
18(b) 0 busyout board
PCSS WARNING OFF release board PCSS
23(c) 0 None WARNING OFF
36 (d) 4368 none
125 (e) None MINOR ON
2172 (f) 0 None WARNING ON
257 65535 Control Channel
Test (#52) MINOR ON test board PCSS sh r 20
257 (g) Any None
267 (f) 0 None WARNI NG ON
513 (h) Any None MINOR ON t est board PCSS sh
769 (i) 4358 None
1025 (j) 4363 NPE Audit Test
(#50) test board PCSS l r 20
1281 (k) Ringing Application
Test (#51) MINOR ON test board PCSS r 2
1538 (l) Any None WARNING/
MINOR ON
1793 (m) Neon Test (#220) MINOR ON test board PCSS r 2
3840 (n) Any None
3999 (o) Any None