DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page8-75clear interface
8
Parameters
None.
Help Messages
If the system technician presses HELP after entering "clear errors," the following
message will be displayed:
Entry is not required
Error Messages
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message will be displaye d:
All maintenance resources busy; try again later
Output
If the clear errors command is successful, the following message will be
displayed on the SAT:
Command successfully completed
If the clear errors command is unsuccessful, the following message will b e
displayed on the SAT:
Error encountered, can’t complete request
Feature Intera c tions
Cleared errors can be displayed using the "display errors" command.
clear interface
This command clears all values of counters maintained by t he processor
interface.