DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-1355TAPE (Tape Unit) [G3iV1.1-286]
10
NOTE:
This test does not check for tape cartridge data consistency, nor does it
check the integrity of every block on tape.
Tape Diagnostic Test (#66)
This test activates the diagnostic tests built into the Maintenance/Tape Processor
(MTP) firmware on the TN773 Processor circuit pack. The test verifies the basic
read/write capability of the tape drive and tape cartridge. Also, the test performs
controller/MTP hardware diagnostics.
The test reads from the tape and performs write verification testing by writing
data into a maintenance block and reading it back. It also perfo rms a tape drive
head step check by advancing the tape drive head t hrough all even streams on
the tape (streams 0 through 18) to make sure the head is operational.
The test does not test every data block on the tape.
Table 10-408. TEST #65 Tape Read/Write Test
Error
Code Test
Result Description/ Recommendation
1029 to
1030
and
2011 to
2051
ABORT Refer to the STBY-SPE (Standby SPE) Maintenance
documentation for a description of these error codes.
9000’s ABORT
or FAIL Refer to Table A in ‘‘Tape Unit Aux Data/Error Codes
Tables’’ and follow the recommended repair strategy for
specific Aux Data.
Any
Others ABORT
or FAIL Refer to Table B in ‘‘Tape Unit Aux Data/Error Codes
Tables’’ and follow the recommended repair strategy for
specific Aux Data.
PASS All tape hardwar e is in good workin g order. Passin g this
test does not guarantee that every single data block on
the tape cartridge can be read or written to.
Continued on next page