DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-330CO-TRK (CO Trunk)
10
3. PBX On-Hook first (Drop Message): Open the Tip-Ring Loop, no loop
current
a. CO Response: Open circuit on Tip
4. CO On-Hook first (Disconnect): Open circuit on Tip, no loop current
Hardware Error Log Entries and Test to Clear
Values
Table 10-92. CO Trunk Error Log Entries
Error
Type Aux Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
010 Any Any Any test port PCSSpp sh r 1
1 (a) 57347 None
15 (b) any Port Audit Update
Test (#36)
18 0 busyout trunk
<grp>/<mbr> WARNING OFF release trunk
<grp>/<mbr>
130(c) None WARNING ON test trunk <grp>/<mbr>
257 (a) 50176 None
513 (a) 57364 None MAJ/MIN/
WRN2ON
769 (a) 57392 None MAJ/MIN/
WRN2OFF
1025 (e) Any Demand
Diagnostic Test
(#3)
MAJ/MIN/
WRN2OFF test port PCSS sh r 2
1281 (e) Any Demand
Diagnostic Test
(#3)
MAJ/MIN/
WRN2ON test port PCSS sh r 3
1537 Dial Tone Test (#0) MAJ/MIN/
WRN2OFF test port PCSS l r 2
1793 Loop Around and
Conference Test
(#33)
MAJ/MIN/
WRN2ON test port PCSS l r 3
2049 NPE Cross Talk
Test (#6) MAJ/MIN/
WRN2ON test port PCSS l r 3
Continued on next page