DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-429DID-DS1 (DS1 DID Trunk)
10
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. DS1 Interface circuit pack detects a hardware error. The Aux Data field
contains the Error Type: 57476, on-hook before wink; 57477, on-hook
before ready to receive digits; 57485, wink too short for valid signal.
Escalate the error.
1. Run the Short Test Sequence first. If al l t ests pass, run th e Long T est Seq uence. Refer t o the app ropri ate
test description and follow the recommended procedures.
2. This alarm will only be raised when the System-Parameter Country form has the Base Tone Genera tor
field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are
out of service, then the alarm will be upgraded to a MAJOR alarm.
3. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set
options command. If the Minor alarm is not downgraded by the set options values, the Minor alarm is
upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
Direct Inward Dial Trunk M aintenance Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
010 Any Any Any test trunk <grp>/<mbr>
sh r 1
1 (a) Any
15 (b) Any Port Audit and
Update Test (#36)
18 (c) WARNING OFF release trunk
<grp>/mbr>
130 (d) None WARNING ON test trunk <grp>/<mbr>
257 (e) 57474
57473
513 (f) 57392 None MIN/MAJ2OF F
769 (g) 57393 None MIN/MAJ2OFF
1281 Conference Circuit
Test (#7) MAJ/MIN/
WRN3ON tes t trunk <grp>/<mbr> l
1537 NPE Crosstalk Test
(#6) MAJ/MIN/
WRN3ON tes t trunk <grp>/<mbr> l
1793 (h) ON test board PCSS l
2305(i) 50944 None MIN/MAJ2OFF
3840 (j) Port Audit and
Update Test (#36)