DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-1533UDS1-BD (UDS1 Interface Circuit Pack)
10
125(d) none None MIN/ WRN3ON
257 65535 Control Channel
Loop Test (#52) MINOR ON test board PCSS l r 20
257(e) Any None
513(f) Any MIN/ WRN3ON
514(g) 46086 MIN/ WRN3ON
769(h) 46085 MIN/ WRN3ON
770(i) 46096 MIN/ WRN3ON
1025(e) 4363 NPE Audit Test
(#50)
1281 Any Loss of Signal
Alarm Inquiry
Test (#138)
MIN /WRN3OFF test board PCSS
1300(j) A ny Loss Of Signal
Alarm Inquiry
Test (#138)
WARNING OFF test board PCSS
1301(k) Any Loss Of Signal
Alarm Inquiry
Test (#138)
WARNING OFF test board PCSS
1302(l) A ny Loss Of Signal
Alarm Inquiry
Test (#138)
MIN/ WRN3OFF test board PCSS
1303(m) Any Loss Of Signal
Alarm Inquiry
Test (#138)
MIN/ WRN3ON test board PCSS
1310(n) Any Board Loopback
Test (#1209) MINOR ON test ds1-loop PCSS
ds1/csu-loopback-tests
1311(o) Any Equipment
Loopback Test
(#1210)
MIN/ WRN3OFF test ds1-loop PCSS
ds1/csu-loopback-tests
1312(p) Any Repe ater
Loopback Test
(#1211)
MIN/ WRN3OFF test ds1-loop PCSS
ds1/csu-loopback-tests
Table 10-454. DS1 Interface Circuit Pack Maintenance Error Log Entries — Continued
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
Continued on next page