DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-600DT-LN-BD (Data Line Circuit Pack)
10
DT-LN-BD (Data Line Circuit Pa c k )
Refer to XXX-BD (Common Port Circuit Pack) Maintenance documentation for
circuit pack level errors. See also DAT-LINE (Data Line Circuit Port) Maintenance
documentation for related line information.
1. Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier
designation (for example, A, B, C, D, or E); and SS is the address of the slot in the
carrier where the circuit pack is located (for example, 01, 02, ..., etc.).
MO Name As
It Appears in
Alarm Log Alarm
Level
Initial System
Technician
Command to Run1Full Name of MO
DT-LN-BD MIN test board PCSS sh Data Line Circuit Pack
DT-LN-BD WRN te st board PCSS sh Data Line Circuit Pack