DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-1426TIE-DS1 (DS1 Tie Trunk)
10
Hardware Error Log Entries and Test to Clear
Values
DS1 Tie Trunk Maintena nce Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
010 Any Any Any test trunk
<grp>/<mbr> sh r 1>
1 (a) 57476
57477
57485
57487
15 (b) Any Port Audit and
Update Test (#36)
18 (c) 0 busyout trunk
<grp>/<mbr> WARNING OFF release trunk
<grp>/<mbr>
130 (d) None WARNING ON test trunk
<grp>/<mbr>
257 (e) 57473
57474
513(f) 57392 DS1 Tie Trunk
Seizure Test (#136) MIN/MAJ2
769(g) 57393 DS1 Tie Trunk
Seizure Test (#136) MIN/MAJ2
1025 DS1 Tie Trunk
Seizure (Test #136) MAJ/MIN/
WRN3OFF test trunk
<grp>/<mbr> r 2
1281 Conference Circuit
(Test #7) MAJ/MIN/
WRN3ON test trunk
<grp>/<mbr> l r 4
1537 NPE Crosstalk
Test (#6) MAJ/MIN/
WRN3ON test trunk
<grp>/<mbr> l r 3
1793 (h) test board PCSS long
2305(i) 50944 DS1 Tie Trunk
Seizure Test (#136) MIN/MAJ3OFF
Continued on next page