DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-898MET-LINE (MET Line)
10
Table 10-256. TEST #60 MET Line Station Lamp Updates Test
Error
Code Test
Result Description/ Recommendation
1 ABORT This port may have been busied out by system
technician.
1. Look in the Error Log for Error Type 18 (port busied
out) for this port. If t h i s e rr o r t ype is present, then
release the port via the release station
<extension> command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at one-minute intervals a
maximum of five times.
4. If the test continues to abort, escalate the problem.
2 ABORT Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
3 ABORT Station is in ready-for-service or out-of-service state.
This may be due to wiring or an unplugged or defective
set.
1. Make sure terminal is connected and the wiring is
correct.
2. Retry the command at 1-minute intervals a maximum
of 5 times.
3. If the test continues to abort, escalate the problem.
Continued on next page