DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page10-1018PDMODULE, TDMODULE (Data Module)
10
Data Module Internal Loop Around Test (#175)
This test verifies that a data message can be sent from the PBX, through the
building wiring, through an internal looparound path in the data module under
test, and back to the PBX. Figure 10-75 shows the hardware configuration used
for this test.
FAIL Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to fail, escalate the problem.
PASS Data Module Audits passed. This digital po rt c ircu it
pack is functioning properly.
1. If complaints still exist, investigat e by u si ng o t he r
port tests, and by examining the data module
options, wiring, and connections.
Table 10-291. TEST #17 Data Module Audits Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page