DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page8-472status link
8
Output
The following fields represent values of counters read from the Packet Interface
board. These counters are not initialized on board insertion. It is therefore
recommended that "clear link" command be issued and th e counters are read
after a period of time (15 min) to get a reliable readout.
Link Number The Processor Interface link number (1-8).
Link Status The state of the link, valid states are:
—in-service
PI link is currently up and providing service.
maintenance busy
The PI link has been busied out by system
technician.
— disconnected
The PI link is currently down. Check the Hardware
Error Log for more information on why the link is not
in-service.
Destination A character string identifying the link destination type.
The valid types are: "ISDN-LNK", "ISDN-TRK", "TIE-DS1",
"PDMODULE", "TDMODULE", and " EIA LINK".
Dest Status The status of the link destination. Valid states are:
"in-service", "in-service/idle", "in-service/active", and
"out-of-service", "manual OOS", "standby", "awaiting call",
"disconnected", "out-of-service-NE", and
"out-of-service-FE".
Port The destination port, this port is logically connected to
the Processor Interface.
Destination Information Field One of the following will be present depending on the
type of link destination.
—Sig G rp
The signaling group number, valid for "ISDN-LNK".
—Trk/Mem
The trunk group/member, valid for "ISDN-TRK" and
"TIE-DS1".
—Ext
The data module extension, valid for "PDMODULE"
and "TDMODULE".