DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123 Issue 1
April 1997
Maintenance Object Repair Procedures

Page10-91ANN-BD (Announcement Circuit Pack)

10
!WARNING:
All alarms are upgraded to MAJOR when the BASE Tone Generator is set to 12. (France).
Notes:

a. Error Type 1This error indicates the circuit pack totally stopped

functioning or it was physically removed from the system.

1. Run the Short Test Sequence first. If all t ests pass, run the Long Test S equence. Ref er to t he appropr iate
test description and follow the recommended procedures.
1538(k) Any None MINOR ON
1793 Angel-SP
Handshake Test
(#208)
MINOR ON test board PCSS l r 3
17680 In-line Error
2049(l)
(m) Clock Match
Inquiry Test (#212) MINOR ON test board PCSS sh r 3
17674 In-line Error
2305 140AY Loop
Around Test (#210) MINOR ON test board PCSS sh r 3
2561 Super Frame
Match Inquiry Test
(#211)
MINOR ON test board PCSS sh r 3
17676 In-line Error
2817(l) Announcement
Checksum Test
(#209)
MINOR ON test board PCSS sh r 3
17682 In-line Error
17699
(m) In-line Error
3840(n) Any None
3999(o) Any None
Table 10-32. Announcement Circuit Pack Error Log Entries — Continued
Error
Type Aux
Data Associated Test
Alarm Level (See
WARNING
message below) On/Off
Board Test to Clear Value
Continued on next page