Block Pending CA/PC

When enabled, the radio will ignore all successive Call Alerts (after receiving a Call Alert) with a different ID than the one originating the pending call. Factory default is Disabled.

Rotary Switch (Scan Prgm)

Use the up/down arrow keys to define the operation of the Channel Rotary during scan programming when BOTH Zone and Channel selection are from the radio menu (i.e., the rotary is not used). The rotary can be used to step through either CHANNELS or ZONES during scan programming. This feature is ONLY applicable when both the zone and channel selections are from the menu. Factory default is Channel.

Selectable Keypad Mute

When enabled, the user may mute the keypad chirps from the radio menu. A mute selection must also be selected on the menu screen (F4/F3/F3/F4). Factory default is Enabled.

Short Keypress Duration (ms)

This value determines the amount of time that a key must be pressed to be considered a valid short keypress. An example of a Short Keypress would be pressing a digit on the keypad when entering a Private Call ID. Valid entries are 50 to 750 ms in 50 ms increments. Factory default is 50 ms.

Long Keypress Duration (ms)

A long keypress involves pressing and holding a key for a period of time to enable a radio function or feature. This means that you must press and hold the key down for the time specified by this field. Valid entries are 250 to 3750 ms in 250 ms increments. Factory default is 1000 ms (1 second).

Maximum Channels (Talkgroups)

This is a read-only field that indicates the maximum number of channels/talkgroups that a radio can access.

Radio Cloning

Certain radio models permit direct radio <-> cloning with a special cloning cable. If this feature is not desired, select disabled.

Rotary Alert (Factory default is Rollover Alert)

Use the up/down arrow keys to select the type of Rotary Alert for Continuous Rotary control models. The type of Continuous Rotary Alerts are:

Rollover Alert - Turning the Rotary control passed all programmed channels in either direction will cause an alert tone (beep) and the display will indicate "UNPROG."

Elec. Stop - Turning the Rotary control passed the first channel position in either direction will cause an alert tone.

None - Turning the Rotary control causes no alert tone.

Secure Equipped

Use the UP/DOWN arrow keys to enable secure operation for radios equipped with the secure hardware option. Setting this field to Yes allows access to the secure screens.

Caution

The user must make sure that the secure hardware is installed in the radio when setting this field to Yes, otherwise it will lead to improper operation of the radio.

Home Mode Selection

This feature allows a radio operator to traverse to a dedicated zone/channel by a short press of the Home button (available in portable radios). A long press of the Home Button will program the Home Mode to be set to the radio’s currently selected zone/channel.