Motorola MT2000 manual Time-Out Timer Table sec

Models: MT2000

1 304
Download 304 pages 23.22 Kb
Page 139
Image 139

CHANGE/VIEW

MTSX RSS

 

 

FIELD DEFINITION:

Mic AGC (Automatic Gain Control)

Use the UP/DOWN arrow keys to select the microphones which will use the AGC feature. The AGC will automatically raise or lower the gain of the microphone to keep the audio level near a pre-determined level.

The choices are Internal, External, Internal and External, or the default value of Disabled.

Time-Out Timer Table (sec)

These values are used by the personalities for the Time-Out Timer (TOT) values. Each personality can select its own time-out timer value from the four that are on this screen.

UP/DOWN arrow keys select the four TOT values available to each personality. Each conventional channel and trunking personality may reference one of these four values. TOT values from 15 to 465 seconds may be selected in 15 second increments. An Infinite value is also available.

If the radio is transmitting and the TOT time expires, the radio is automatically dekeyed and a continuous alert tone will be generated for as long as the PTT button is pressed. To continue transmitting, the PTT button must be released and the radio rekeyed.

Factory default values are: Infinite, 30, 60, and 120 seconds.

6-12

68P81074C50

 

 

Page 139
Image 139
Motorola MT2000 manual Time-Out Timer Table sec