FIELD DEFINITIONS:

Voice On Control Capable

When a radio is VOC Capable, it is able to handle the transition of a site going into and out of Voice On Control Mode without entering the Out-of-Range state.

Factory default is Disabled.

RSSI Acceptable Threshold

This field defines the minimum signal strength (RSSI value) for a radio to determine that it is in range of a valid voice or control channel. If a site enters Voice on Control, the radio will remain locked onto that site. One of the possible conditions that would cause the radio to roam to another site (or possibly enter the Out-of-Range state) is when the radio determines there is about 5 seconds of low signal strength (RSSI below this threshold) on the last active CC. The range of values for this field is 0 to 255.

Factory default is 74.

Voice On Control Site Lock Time

This field defines the maximum time (in seconds) a radio will remain locked onto a Voice on Control or Control Site before it will attempt to lock onto another site (and possibly enter the Out-of-Range state). The range of values for this field is 15 to 255 in 1 sec. intervals.

Factory default is 60.

Voice On Control Pended Emer Time

This field defines the necessary data fields for operation on a Voice on Control capable site. When a site enters VOC Mode, its Control Channel is surrendered for a Voice Call. All radios that are not Voice On Control Capable will go out of range at that time. The range of values for this field is 500 to 6000 msec in 25 msec intervals..

Factory default is 500.

Voice On Control Activation Time

This field determines the maximum time (in 25 mS increments) that the radio will delay before sending in ISW requests upon receiving a system Status OSW indicating the site is exiting Voice On Control Mode.

he range of values for this field is 500 to 6000 ms in 25 msec intervals.

Factory default is 500.