CHANGE/VIEW | MTSX RSS |
|
|
FIELD DEFINITIONS:
Nuisance Mode Delete
This option allows you to temporarily delete
Priority Scan Alert
If this option is enabled, the radio will audibly alert the user when it unmutes on a priority channel while scanning. One beep is generated for the priority talkgroup in a trunked scan list, or for the first priority channel in a conventional scan list. Two beeps are generated for the second priority channel in a conventional scan list. Factory default is Disabled.
Rx Hold Time (sec)
This is the amount of time the radio remains on a channel after a message has been received before scanning resumes. Valid entries are 0 to 255 seconds in 1 second increments. Factory default is 3 seconds.
HUB Suspends Scan
Use the UP/DOWN arrow keys to Enable/Disable the HUB Suspends Scan feature. HUB Suspends Scan will determine if the scan operation will be suspended while the microphone is removed from the hang up box. If HUB Suspends Scan is enabled, scan operation will be suspended while the microphone is removed from the hang up box. This will allow the user to complete a conversation while scan is suspended. For portables this option is applicable when a Vehicular Adapter is used.
The factory default is Disabled.
Carrier Detect Required
When this option is enabled, the priority channels will stop on carrier squelch detect but only unmute on the standard signaling conditions programmed for that channel. Factory default is Disabled.
Priority Chan Marking
When this option is enabled and the radio is in Priority Scan Mode, the radio checks the channel for activity and proper PL. If the channel has carrier but the wrong PL or no PL, the channel is marked so the radio will not recheck for the proper PL. The radio will not unmute on this channel until the carrier is dropped.
This is done to prevent the PL decode time from being added to the audio hole time when the radio is unmuted on a
Monitor Hold Time (sec)
Scan monitor hold time is the time the radio remains on a conventional channel during scan after the monitor button has been released. Valid entries are 0 to 255 seconds in 1 second increments. Factory default is 6 seconds.
Voting Scan
Conventional Voting Scan is used to select the best repeater to use in a
Auto Scan enabled
Warning
Having more than 7 list members in a conventional scan list used for Conventional Voting Scan may degrade performance, resulting in missed transmissions.