CHANGE/VIEW

 

 

Decoder 2 Call Type

Use the Up/Down arrows to scroll through the available selections.

This field dictates the Decoder 2 Call Type to be used: Individual or Group. The Factory Default is Group.

Decoder Option

Use the Up/Down arrows to scroll through the available selections. This field controls the number of decoders (1 or 2) and the decode sequences to be used on this Quik-'Call II System.

This field controls the number of decoders (1 or 2) and the decode sequences to be used on this Quik-Call II System. The Factory Default is (1) A-B.

Available selections include:

(1) A-B

(1)A-B, (2) A-C

(1)A-B, (2) C-B

(1)A-B, (2) B

(1)A-B, (2) C

(1)A-B, (2) C-D

The factory default is (1) A-B

Codes

Use the Up/Down arrows to scroll through the available selections or directly enter the desired value. Codes vary depending on the Signalling System Type. This field contains a code that represents a Quik-Call II Tone frequency. Codes vary depending on the Signalling System Type selected. The Factory Default is Code A, B, C, or D.

Note: All codes A, B, C, and D should never have the same values.

 

 

Factory Defaults

 

 

Signalling

Code A

Code B

Code C

Code D

Type

 

 

 

 

Motorola

138

121

13

18

GE

44

7

38

51

Plectron

P1

P10

P25

P36

Federal

F1

F10

F16

F20

Freq (Hz)

Use the Up/Down arrows to scroll or directly enter the available tones. This field represents the frequency of audible tone in 0.1 Hz steps. Values from 288.5 to 3010.0 Hz in 0.1 Hz increments are allowed.

Note: All tones A, B, C, and D should never have the same values.

Factory Defaults

Signalling

Code A

Code B

Code C

Code D

Type

 

 

 

 

Motorola

288.5

600.9

1950.0

2840.0

GE

457.5

607.5

1077.5

1207.5

Plectron

643.0

950.0

1820.0

2932.0

Federal

643.0

1299.0

2084.0

2856.0