Chapter 3: FaxFinder Server Software Screens

 

 

 

 

 

 

 

Modem Configuration Screen Field Definitions (cont’d)

 

 

Field Name

Values

Description

 

 

Routing Definition

Key link,

Many PBXs send a series of DTMF Tones to the Server

 

 

 

Description link

when a call is being established. The Routing Definition

 

 

-and-

field defines where the Extentsion number is in the series

 

 

Hide Key,

of tones. The Extension number is used by the FaxFinder

 

 

Hide Description

 

 

Server to route the received fax to the appropriate email

 

 

 

 

 

 

address.

 

 

 

Routing Definition allows a User Defined setting for PBXs

 

 

 

using DTMF routing that is not currently in the Routing

 

 

 

field.

 

 

 

The Key URL will display the definition of the special

 

 

 

character sequence that can be used to create a custom

 

 

 

mode code definition. The definition is used by the

 

 

 

FaxFinder Server to extract the extension number from

 

 

 

the DTFM tones sent to the PBX.

The Description URL will display how the FaxServer will interpret the custom definition.

In an example of the Routing set for Avaya Mode Code, the Description in the Routing Definition is displayed as follows:

 

 

In the Description above, the # is used as a delimiter

 

 

between sections of the custom routing definition. There

 

 

are two calling type characters, followed by 4 calling

 

 

number characters, followed by 4 DTMF extension digits.

 

 

The ? tells the Server to use the definition of Max DTMF

 

 

Digits for the number of extension digits. All fields are

 

 

separated by a # tone field separator.

Max Baud Rate

2400 – 33,600 bps

The value in this field determines the maximum baud rate

 

 

used for fax calls on the POTS modem. Set at less than

 

 

33,600 bps only if there are problems with the phone line.

Tone Dial

on, off

Set this field to “on” if your POTS line supports tone

 

 

(DTMF) dialing. Set this field to “off” if the POTS line

 

 

supports rotary dialing only. Default = on.