CHAPTER 5. PERIPHERAL HARDWARE FUNCTIONS

Fig. 5-25 Serial Operating Mode Register (CSIM) Format (2/2)

Wake-up function specification bit (W)

WUP

0IRQCSI set at end of every serial transfer in each mode.

Used only in SBI mode. IRQCSI is set only when the address received after bus

1release matches the slave address register data (wake-up status). SB0 is high impedance.

Note If WUP = 1 is set during BUSY signal output, BUSY is not released. With the SBI, the BUSY signal is output after the BUSY release directive until the next fall of the serial clock (SCK). When setting WUP = 1, it is necessary to confirm that the SB0 pin has been driven high after BUSY is released before setting WUP = 1.

Signal from address comparator (R)

COI*

Clearing Condition (COI = 0)

Setting Condition (COI = 1)

 

 

When slave address register (SVA) and

When slave address register (SVA) and shift

shift register data do not match

register data match.

 

 

*A COI read is valid only before the start or after completion of a serial transfer. During a transfer an indeterminate value will be read. Also, COI data written by an 8-bit manipulation instruction is ignored.

Serial interface operation enable/disable specification bit (W)

 

Shift Register

Serial Clock

IRQCSI Flag

SO/SB0 & SI Pins

 

Operation

Counter

 

 

 

0

Shift operation

Cleared

Retained

Port 0 function only

disabled

 

 

 

 

CSIE

 

 

 

Function in each

 

Shift operation

 

 

1

Count operation

Settable

mode plus port 0

enabled

 

 

 

function

 

 

 

 

76