Nortel Networks NN43119-101 manual Description, Potential causes, Action

Models: NN43119-101

1 136
Download 136 pages 43.5 Kb
Page 116
Image 116

Troubleshooting the IP Softphone 2050

Description:

These messages indicate that the connection with the communication server cannot be established. The IP Softphone 2050 sets a random retry time, after which it attempts to reconnect. This process repeats until the IP Softphone 2050 successfully connects.

The “Connecting...” message appears briefly (or not at all) under the following conditions:

The communication server is running and reachable.

The IP Softphone 2050 is directed to the correct IP address.

The “Server unreachable” message appears when the IP Softphone 2050 encounters a problem contacting the communication server.

Potential causes:

Network down

Computer not connected to the network

Invalid communication server settings in the Configuration Utility

Invalid communication server settings in DHCP configuration

Communication server down

Action:

Ping another station on the network.

Ping the communication server.

Use the Server dialog box in the Settings window to verify the communication server IP address and port number (for more information, see “Server” on page 82).

Verify correct configuration of the communication server. Check for the following: an available port, an available license, and for correct security.

116

Page 116
Image 116
Nortel Networks NN43119-101 manual Description, Potential causes, Action