4.5.2 Setting COS (Class of Service)
Parameters
Parameter Value Range
(default) Description/Function Reference
Authorization of 1. Yes If set to “Yes”, Subscribers can utilize the
M.W.N.
Message 2. No Message Waiting Notification feature.
p.3-38. 3-41
Notification (NoI [Note]
Notification
If you took the Quick Setup step to create
Setting
mailboxes, this parameter in COS No. 1 has been
p.4-22
already set to “Yes”.
Beeper
Callback No.
Entry Mode
1. Select
2. Without
3. Before
4. After
5. Disable
(None)
Allows or prohibits the Subscriber to utilize the
Callback
Callback Number Entry feature.
Number
Select: After message recording, the VPS will
Entry
ask the caller if the message is urgent.
p.3-7
If specified as urgent, the VPS will ask
Number to
Dial
the caller to enter his callback number.
p.4-23
Without: Without message recording, the VPS Type
will ask the caller to enter his callback
p.4-24
number.
Max. Digits
Before: Before message recording, the VPS will
for
ask the caller to enter his callback
Callback
number.
No./
Callback
After: After message recording, the VPS will
No. Entry
ask the caller to enter his callback
Interdigit
number.
Time-Out
p.4-67
Disable: The VPS will not ask the caller to enter
his callback number.
System
Callback
[Notes] .
No.
l
To utilize this feature, the beeper number must
p.4-68
include the callback number entry code “X”.
See “Notification Setting” on page 4-22.
l
When “Disable” is selected or the caller does
not enter his callback number, System Callback
No. will be displayed on the beeper’s display.
MWL 1. Yes Lets the VPS turn on the message waiting lamp
M.W.N.-
Notification for 2. No again, if unplayed messages are still left in the
Lamp
Unreceived (None) mailbox after the Subscriber’ access.
p.3-41
Message
Device
Notification for
Unreceived
Message
1. Yes Lets the VPS call devices, if unplayed messages
2. No are still left in the mailbox after the Subscriber’s
(None) access.
M.W.N.-
Device
p.3-38
Type
p.4-24