4.5.5 System Parameter Settings
Parameter
System
Callback No.
Value Range
(default)
Up to 32
digits
(None)
1
Description/Function
Specifies a telephone number displayed on
Subscriber’s beepers as a callback number when
“Type” is set to “Beeper”.
[Note]
If “Beeper Callback No. Entry Mode” is activated,
the callback number entered by the caller will be
displayed on the destination beeper instead of this
system callback number.
4.5.5.6.4 External Message Delivery Parameters
Used to control the handling of External Message Delivery calls.
System Administration Top Menu + 1 + 5 + 6 + 4
Reference
Callback
Number
Entry
p.3-7
Number to
Dial
p.4-23
Type
p.4-24
Beeper
Callback NC
Entry Mode
p.4-33
Program - System Parameter - Others - External Message Delivery Menu
Retry Times (O-9 times) ----
Busy Delay (l-60 min.) ------ ----
No-answer Delay (I-120 min.) ---------------
Outgoing Call Ports -- _-__ --__---
Message Length’(l-6 min.)
Max. Message for Mailboxes (l-l 00 msgs)
System External Message Delivery Duration Time (l-9 min.)-
Company’s Telephone No. ~-
:3
:3
: 60
: l,Z 3, 4
:3
:3
:3 ...........
. ...........
Parameter
Retry Times
Value Range
(default) Description/Function Reference
O-9 times Specifies the number of times that an external
E.M.D.
(3) message delivery call should be attempted when
Service
the destination is busy or if there is no answer.
p.3-22
Busy Delay 1 -60 min.
(3)
Specifies the length of time in minutes the VPS is
to wait after a busy condition before trying to
deliver the message again.

4-68

System Administrator