APPENDIX C BAR CODE LABEL SPECIFICATION

This appendix provides specifications for creating bar code labels used on cartridges in Plasmon AIT libraries. The specifications are defined to both standardize the label and allow users the option of purchasing or printing their own labels.

Overview

The AIT cartridge label uses the bar code symbology of USS-39. A description and definition of this symbology is available from the Automatic Identification Manufacturers (AIM) specification Uniform Symbol Specification (USS-39) and the ANSI MH10.8M-1993 ANSI Barcode specification.

Bar Code Characters

Print the bar code in accordance with the latest revision of the ANSI MH10.8M specification (Code 3-of-9). The bar code can have between seven and nine characters as shown in the following table.

Top

1 start character

 

4 to 6 alphanumeric characters, which you select

 

from the following table.

 

1 checksum character

Bottom

1 stop character.

Checksum Character

NOTE

The checksum character is mandatory to these labels.

The checksum character is computed as the character corresponding to the modulus 43 sum of all the values in the eight character section of the bar code. Character values are derived from the following table.