Table 10. Cartridge Inventory Fields

 

 

Cartridge

Description

Inventory

 

Field

 

Index:

Displays the element index for which the information is

 

being displayed.

 

 

Type:

Indicates the type of element: either a cartridge slot, drive,

 

or robot.

 

 

Warning:

Displays 0 if there are no failures or errors associated with

 

this element; or, displays an error code. See Appendix C for

 

a list of error codes and corrective actions.

 

 

Occupied:

Indicates whether the specified element contains a cartridge

 

(1) or not (0).

 

 

Valid:

Indicates whether the Occupied flag is accurate (1) or is

 

questionable (0).

 

 

Accessible:

Indicates if the element is accessible (1) or not (0). If the ele-

 

ment is a magazine slot, it is accessible if the magazine is

 

installed. If the element is the tape drive, it is accessible if

 

the drive is installed in the drive bay and does not contain a

 

cartridge.

 

 

Present:

Shows whether the tape drive or magazine is installed

 

(1) or not (0).

 

Note: If the element references a slot, this flag indicates

 

whether the magazine is installed.

 

 

Label/Valid:

Indicates whether the Label field is valid (1) or not (0).

 

 

Label Error:

Indicates if the barcode scan was successful (0) or displays

 

an error condition:

 

60 – The barcode scanner could not read the barcode label

 

because there was no label on the cartridge.

 

61 – The barcode scanner could not read the barcode label

 

because the label was unreadable.

 

62 – The barcode scanner could not read the label because

 

the magazine is not present.

 

63 – The barcode scanner could not read the label for a sin-

 

gle slot because the inventory is questionable.

 

64 – The barcode scanner could not read the label because

 

of a problem with the checksum character.

 

67 – The library could not collect barcode data for the fixed

 

slot because of a firmware or hardware problem.

 

 

Sndvol Match:

Indicates whether the cartridge label matched the template

(Send

sent with the last SCSI SEND VOLUME TAG command (1)

Volume

or not (0).

Match)

 

 

 

Plasmon V15 AIT Tape Library User Manual Page 64

Page 66
Image 66
Plasmon V15 manual Cartridge Description Inventory, Field