LCD

Description

Corrective Action

Code

 

 

198

Robot full before command.

Open the library door and remove the cartridge from the

 

The robot, all slots, and all

robot gripper.

 

drives contain a cartridge

Reset the library.

 

when an Initialize Element

 

 

Status command was

 

 

requested.

 

 

 

 

199

Tape in drive. A cartridge is

Eject the cartridge from the tape drive and remove it

 

already loaded in the destina-

manually (see Ejecting a cartridge Manually in Chapter

 

tion tape drive.

6).

 

 

Note: This error only occurs when the library is operat-

 

 

ing in Sequential mode.

 

 

 

200

X axis does not move. The

Open the door and remove the magazines. Look for any-

 

robot could not move along

thing that might be obstructing the robot’s path along the

 

the horizontal axis.

horizontal axis.

 

 

Make sure the library and tape drives are not being used

201

X axis has failed home. The

by any host, then reset the library from the operator

 

robot could not return to the

 

panel.

 

home position along the hori-

 

If there are no obstructions and the error persists, con-

 

zontal axis.

 

tact your service provider.

 

 

202

X axis position sensor

 

 

failed. The library could not

 

 

complete a move along the

 

 

horizontal axis.

 

 

 

 

203

X axis EOT fail. The library

Open the door and remove the magazines. Look for any-

 

could not detect the end-of-

thing that might be obstructing the robot’s path along the

 

travel sensor on the horizontal

horizontal axis.

 

axis.

Make sure the library and tape drives are not being used

 

 

by any host, then reset the library from the operator

204

X axis home sensor fail. The

panel.

 

library could not detect the

 

If there are no obstructions and the error persists, con-

 

horizontal axis home sensor

 

tact your service provider.

 

(safe rotate position).

 

 

 

 

 

205

X axis scan failed. The library

 

 

could not complete a move

 

 

along the horizontal axis.

 

 

 

 

207

X axis cal fail. The robot posi-

 

 

tion along the horizontal axis

 

 

could not be calibrated.

 

 

 

 

213

Invalid Xcard configuration.

Make sure the library and tape drives are not being used

 

An invalid combination of

by any host, then reset the library from the operator

 

expansion cards is installed in

panel.

 

the library.

If the error persists, contact your service provider. An

 

 

expansion card may not be properly installed or the

 

 

wrong card is installed.

 

 

 

Plasmon V15 AIT Tape Library User Manual Page 128

Page 130
Image 130
Plasmon V15 manual Axis position sensor