LCD | Description | Corrective Action | |
Code |
|
| |
198 | Robot full before command. | Open the library door and remove the cartridge from the | |
| The robot, all slots, and all | robot gripper. | |
| drives contain a cartridge | Reset the library. | |
| when an Initialize Element |
| |
| Status command was |
| |
| requested. |
| |
|
|
| |
199 | Tape in drive. A cartridge is | Eject the cartridge from the tape drive and remove it | |
| already loaded in the destina- | manually (see Ejecting a cartridge Manually in Chapter | |
| tion tape drive. | 6). | |
|
| Note: This error only occurs when the library is operat- | |
|
| ing in Sequential mode. | |
|
|
| |
200 | X axis does not move. The | Open the door and remove the magazines. Look for any- | |
| robot could not move along | thing that might be obstructing the robot’s path along the | |
| the horizontal axis. | horizontal axis. | |
|
| Make sure the library and tape drives are not being used | |
201 | X axis has failed home. The | ||
by any host, then reset the library from the operator | |||
| robot could not return to the | ||
| panel. | ||
| home position along the hori- | ||
| If there are no obstructions and the error persists, con- | ||
| zontal axis. | ||
| tact your service provider. | ||
|
| ||
202 | X axis position sensor |
| |
| failed. The library could not |
| |
| complete a move along the |
| |
| horizontal axis. |
| |
|
|
| |
203 | X axis EOT fail. The library | Open the door and remove the magazines. Look for any- | |
| could not detect the | thing that might be obstructing the robot’s path along the | |
| travel sensor on the horizontal | horizontal axis. | |
| axis. | Make sure the library and tape drives are not being used | |
|
| by any host, then reset the library from the operator | |
204 | X axis home sensor fail. The | ||
panel. | |||
| library could not detect the | ||
| If there are no obstructions and the error persists, con- | ||
| horizontal axis home sensor | ||
| tact your service provider. | ||
| (safe rotate position). | ||
|
| ||
|
|
| |
205 | X axis scan failed. The library |
| |
| could not complete a move |
| |
| along the horizontal axis. |
| |
|
|
| |
207 | X axis cal fail. The robot posi- |
| |
| tion along the horizontal axis |
| |
| could not be calibrated. |
| |
|
|
| |
213 | Invalid Xcard configuration. | Make sure the library and tape drives are not being used | |
| An invalid combination of | by any host, then reset the library from the operator | |
| expansion cards is installed in | panel. | |
| the library. | If the error persists, contact your service provider. An | |
|
| expansion card may not be properly installed or the | |
|
| wrong card is installed. | |
|
|
|