LCD | Description | Corrective Action | |
Code |
|
| |
73 | Stepper Move Fail. The firm- | Make sure the library and tape drives are not being used | |
| ware failed to complete a step- | by any host, then reset the library from the operator | |
| per move. | panel. | |
|
| If the error persists, contact your service provider. | |
|
|
| |
74 | Unoccupied drive bay. A | Install a tape drive or a drive carrier service access | |
| tape drive or service access | cover. | |
| cover is not installed in the | If the error persists, contact your service provider. | |
| drive bay. |
| |
|
|
| |
75 | Internal S/W error. Firmware | Make sure the library and tape drives are not being used | |
| error. | by any host, then reset the library from the operator | |
|
| panel. | |
|
| If the error persists, contact your service provider. You | |
|
| may be asked to supply a diagnostic listing; you may | |
|
| need new firmware. | |
|
|
| |
77 | Interface disabled. The | Set the library to the correct control mode. | |
| library was not in the correct |
| |
| control mode when the opera- |
| |
| tor sent a command. |
| |
|
|
| |
80 | Entry/Exit Port Hardware | Make sure the library and tape drives are not being used | |
| Error. | by any host, then reset the library from the operator | |
|
| panel. | |
87 | EE caddy removed. The | ||
If the error persists, contact your service provider. | |||
| entry/exit port caddy was | ||
|
| ||
| removed at an unexpected |
| |
| time. |
| |
|
|
| |
88 | Entry/Exit Port Motor Error. |
| |
| Excessive current. |
| |
|
|
| |
89 | Caddy not available. The | Replace the caddy as described in Replacing Cartridges | |
| entry/exit port caddy was not | Using the Entry/Exit Port in Chapter 5. | |
| inserted correctly. | If the error persists, contact your service provider. | |
|
|
| |
90 | Drive HW Error. The tape | Use the Reset Tape Drive option on the operator panel | |
| drive could not perform an | to reset the tape drive. | |
| operation because of a hard- | Make sure the library and tape drive is not being used by | |
| ware error. | any host, then reset the library from the operator panel. | |
|
| If the error persists, contact your service provider. You | |
|
| may be asked to supply a diagnostic listing; you may | |
|
| need new firmware. | |
|
|
| |
91 | Command aborted. A diag- | No corrective action required. | |
| nostic command was aborted |
| |
| by the operator. |
| |
|
|
|
Appendix C Page 125