LCD

Description

Corrective Action

Code

 

 

73

Stepper Move Fail. The firm-

Make sure the library and tape drives are not being used

 

ware failed to complete a step-

by any host, then reset the library from the operator

 

per move.

panel.

 

 

If the error persists, contact your service provider.

 

 

 

74

Unoccupied drive bay. A

Install a tape drive or a drive carrier service access

 

tape drive or service access

cover.

 

cover is not installed in the

If the error persists, contact your service provider.

 

drive bay.

 

 

 

 

75

Internal S/W error. Firmware

Make sure the library and tape drives are not being used

 

error.

by any host, then reset the library from the operator

 

 

panel.

 

 

If the error persists, contact your service provider. You

 

 

may be asked to supply a diagnostic listing; you may

 

 

need new firmware.

 

 

 

77

Interface disabled. The

Set the library to the correct control mode.

 

library was not in the correct

 

 

control mode when the opera-

 

 

tor sent a command.

 

 

 

 

80

Entry/Exit Port Hardware

Make sure the library and tape drives are not being used

 

Error.

by any host, then reset the library from the operator

 

 

panel.

87

EE caddy removed. The

If the error persists, contact your service provider.

 

entry/exit port caddy was

 

 

 

removed at an unexpected

 

 

time.

 

 

 

 

88

Entry/Exit Port Motor Error.

 

 

Excessive current.

 

 

 

 

89

Caddy not available. The

Replace the caddy as described in Replacing Cartridges

 

entry/exit port caddy was not

Using the Entry/Exit Port in Chapter 5.

 

inserted correctly.

If the error persists, contact your service provider.

 

 

 

90

Drive HW Error. The tape

Use the Reset Tape Drive option on the operator panel

 

drive could not perform an

to reset the tape drive.

 

operation because of a hard-

Make sure the library and tape drive is not being used by

 

ware error.

any host, then reset the library from the operator panel.

 

 

If the error persists, contact your service provider. You

 

 

may be asked to supply a diagnostic listing; you may

 

 

need new firmware.

 

 

 

91

Command aborted. A diag-

No corrective action required.

 

nostic command was aborted

 

 

by the operator.

 

 

 

 

Appendix C Page 125

Page 127
Image 127
Plasmon V15 manual Entry/Exit Port Hardware