LCD | Description | Corrective Action | |
Code |
|
| |
92 | Drive Offline Error. The tar- | Contact your service provider | |
| geted drive has been taken |
| |
| offline and cannot service |
| |
| command requests. |
| |
|
|
| |
93 | Drive swapped. A drive has | No corrective action required, unless no drive was | |
| been swapped out for another. | swapped. Then contact your service provider. | |
|
|
| |
95 | Drive removed. A tape drive | Power off the library and install a tape drive or service | |
| was removed while the library | access cover. | |
| was powered on. |
| |
|
|
| |
97 | Drive not present. A move | Install a drive in the drive bay or send commands to | |
| was requested to a drive that | another drive. | |
| is not installed. | If a drive is already installed when this message dis- | |
|
| played, contact your service provider. | |
|
|
| |
109 | Check cleaning tape. A clean | Eject the cartridge from the tape drive and remove it | |
| drive operation failed because | manually (see Chapter 6). | |
| the drive did not unload the | Install a new cleaning cartridge into the fixed slot (see | |
| cleaning cartridge within a rea- | Chapter 2). | |
| sonable amount of time. |
| |
|
|
| |
116 | Drive comm failed. The | Check the tape drive SCSI ID and change it, if neces- | |
| library is unable to communi- | sary. | |
| cate with the tape drive. | Make sure the library and tape drives are not being used | |
|
| by any host, then reset the library from the operator | |
117 | Drive comm timeout. The | ||
panel. | |||
| library is unable to communi- | ||
| If the error persists, contact your service provider. You | ||
| cate with the tape drive. | ||
| may be asked to supply a diagnostic listing; you may | ||
|
| ||
|
| need new firmware or a new controller card. | |
|
|
| |
118 | Drive load cmd fail. The | Open the door and remove the magazine. Look for any- | |
| library was unable to load a | thing that might be obstructing the robot’s path along the | |
| cartridge in the tape drive. | horizontal axis. | |
|
| Make sure the library and tape drives are not being used | |
|
| by any host, then reset the library from the operator | |
|
| panel. | |
|
| If there are no obstructions and the error persists, the | |
|
| robot or a tape drive may need to be replaced. Contact | |
|
| your service provider. | |
|
|
| |
119 | Drive not ready. The tape | Make sure the library and tape drives are not being used | |
| drive did not return Ready sta- | by any host, then reset the library from the operator | |
| tus after a reset. | panel. | |
|
| If the error persists, contact your service provider. You | |
|
| may be asked to supply a diagnostic listing; you may | |
|
| need new firmware or a new controller card. | |
|
|
|
Plasmon V15 AIT Tape Library User Manual Page 126