Plasmon V15 manual Could not set alarm

Models: V15

1 138
Download 138 pages 9.8 Kb
Page 131
Image 131

LCD

Description

Corrective Action

Code

 

 

214

Invalid Slot Config. The Max-

Change the Max Addressable Slot to a value greater

 

imum Number of Slots is set to

than 1 (see Setting the Max Addressable Slot Option in

 

1 and the last slot is config-

Chapter 3) or turn off the Clean Slot Option (see Setting

 

ured as a cleaning slot.

the lean Slot Option in Chapter 3).

 

 

 

220

OS failure. The library’s oper-

Make sure the library and tape drives are not being used

 

ating system experienced an

by any host, then reset the library from the operator

 

error.

panel.

 

 

If the error persists, contact your service provider.

221

Could not set alarm. The

 

 

library’s operating system

 

 

experienced an error.

 

 

 

 

222

OS message failure. The

 

 

library operating system expe-

 

 

rienced an error.

 

 

 

 

225

M Bus Timeout. No acknowl-

Ensure no commands are active to the library. Reset the

 

edgement from internal M bus

library. If error persists, contact your service provider.

 

device

 

 

 

 

226

Mbus interrupt timeout. The

Make sure the library and tape drives are not being used

 

robot command processor

by any host, then reset the library from the operator

 

timed out before setting an

panel.

 

interrupt.

If the error persists, the robot may need to be replaced.

 

 

Contact your service provider.

227

Mbus acknowledge failure.

 

 

The robot command processor

 

 

failed to respond to a com-

 

 

mand.

 

 

 

 

230

DHCP server timeout. The

This error occurs only when the optional Ethernet inter-

 

Ethernet DHCP server could

face is installed. Set the network address to Static and

 

not assign an IP address for

set the desired IP address (see Setting Ethernet

 

the library.

Addresses in Chapter 4).

 

 

 

236

SCSI Configuration Error.

If power cycling the library does not recapture this infor-

 

Configuration start ID is

mation, contact your service provider.

 

invalid.

 

 

 

 

237

SCSI Configuration Error.

 

 

Configuration field is invalid.

 

 

 

 

238

SCSI Configuration Error.

 

 

Configuration value is invalid.

 

 

 

 

239

SCSI Configuration Error.

 

 

Configuration buffer ID is

 

 

invalid.

 

 

 

 

Appendix C Page 129

Page 131
Image 131
Plasmon V15 manual Could not set alarm