6.Press the down arrow key to display the Restart Option screen. The screen shows whether the Restart option is on (1) or off (0).

R e s t a r t O p t i o n :

1

7. Press [ENTER] again to display the screen for changing the Restart option.

R e s t a r t

O p t i o n ? 1

8.Use the up or down arrow key to change the setting, then press [ENTER]. The Restart Option screen shows the new setting.

9.Press the down arrow key to display the Next Cartridge Option screen.

N e x t C a r t r i d g e :

?

10.Press [ENTER] to set the next cartridge to 1 or [ESCAPE] to cancel.

11.Press [ESCAPE] to return to the Sequential Mode screen.

Avoiding Interruptions

Although the library has effective methods for resuming operation, it is best to avoid interruptions when the library is operating sequentially. In particular:

Do not reset or power cycle the library unless absolutely necessary. Reset the library only to clear certain error conditions and power off the library only to perform maintenance or to store it. Avoid resetting or power cycling the library when a cartridge is in the tape drive or the robot.

Do not open the door unless absolutely necessary. During operation, open the door only to replace the magazine after the library has processed all the cartridges. Never force the door. The library does not release the door until it completes a cartridge move or load already in progress. Certain applications may also prevent the door from being opened.

Do not remove a cartridge from the tape drive or insert a cartridge into the tape drive. If you want to remove a cartridge, wait until the robot has placed it in the magazine before removing it. If you want to add a cartridge, add it directly to the magazine.

Plasmon V15 AIT Tape Library User Manual Page 62

Page 64
Image 64
Plasmon V15 manual Avoiding Interruptions