Chapter 5: Configuration

Decoded (Internal) Scanners

When this parameter is enabled, the scanner transmits data from PDF417 and MicroPDF417 bar codes containing Character Set ECIs, even when the ECI Protocol is disabled.

ECI Decoder

Setting this parameter to on enables the scanner to interpret any Extended Channel Interpre- tations (ECIs) supported by the scanner. This parameter has no effect on symbols that were not encoded using ECIs.

If this parameter is set to OFF and a symbol that was encoded using an ECI escape is scanned, the scanner transmits the ECI escape followed by the data that was not interpreted.

5.13.2.4 Code 39

Enabled

Setting this parameter to on enables “Code 39”.

Enable Trioptic Code 39

Note: “Trioptic Code 39” and “Full ASCII” should not be enabled simultaneously. The scanner does not automatically discriminate between these two symbologies.

Trioptic Code 39 symbols always contain six characters. Setting this parameter to on allows this type of symbology to be recognized.

Convert To Code 32

Note: “Code 39” must be enabled in order for this parameter to function.

Setting this parameter to on allows the scanner to convert the bar code from “Code 39” to “Code 32”.

Code 32 Prefix

Note: “Convert to Code 32” must be enabled in order for this parameter to function.

When this parameter is enabled, the prefix character “A” is added to all “Code 32” bar codes.

140Psion Teklogix NEO Hand-Held Computer User Manual