Chapter 5: Configuration

Decoded (ISCP)

Code 11

rity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted.

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must be enabled.

Plessy Transmit Check Digit

If the check digit is to be transmitted with the Plessy data, this parameter must be enabled.

Minimum Length

Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Plessy Minimum Length

Minimum lengths for the Plessy bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Length Restriction

Refer to “Length Restriction” on page 142 for details.

Add/Remove Data

Refer to “Add/Remove Data” on page 142 for details.

5.13.3.13 Code 11

Enabled

Set this parameter to on to enable “Code 11”.

Check Digit Verification

The available options for this parameter are MOD 10 Check and Double MOD 10

Check.This parameter uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted.

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must be enabled.

Psion Teklogix NEO Hand-Held Computer User Manual

161

Page 173
Image 173
Psion Teklogix PX750 manual Plessy Transmit Check Digit, Plessy Minimum Length