Chapter 5: Configuration
Decoded (ISCP)
Code 39
Low Power Timeout
To extend laser life, you can select the length of time the scanner remains active following a successful decode. The scanner wakes from low power mode when a bar code is
When you
Note: This parameter is only used if the Trigger Mode has been set to Continuous On and the
Parameter Scanning
Setting this parameter to Enabled allows decoding of parameter bar codes.
Same Read Validate
The data is only transmitted after repeated reads give the same result. The value assigned at this parameter determines the number of reads required, from 0 to 10 times.
Same Read Timeout
Prevents the same bar code from being read more than once. The value assigned determines after what time period the scanner will timeout, from 0 to 2550 msec.
Diff Read Timeout
Prevents unwanted reading of other bar codes on the same label. The value assigned deter- mines after what time period the scanner will timeout, from 0 to 2550 msec.
5.13.3.3 Code 39
Enable
Setting this parameter to on enables “Code 39”.
Full ASCII
If this parameter is enabled, the characters +, %, and / are used as escape characters. The combination of an escape character and the next character is converted to an equivalent ASCII character.
Reading Range
Determines the reading distance from which a bar code can be successfully scanned. The default setting, Extended, allows for increased reading distance.