Chapter 5: Configuration
Decoded (Internal) Scanners
Code 93
5.13.2.11 Code 93
Enabled
Set this parameter to on to enable “Code 93”, or OFF to disable it.
Set Length L1 And Set Length L2
Lengths for “Code 93” can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).
Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 4 to 55.
Length Restriction
Refer to “Length Restriction” on page 142 for details.
Add/Remove Data
Refer to “Add/Remove Data” on page 142 for details.
5.13.2.12 Codabar
Enabled
Set this parameter to on to enable “Codabar”.
Set Length L1 And Set Length L2
Lengths for “Codabar” can be set for Any length, Length within a range, One discrete length, or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).
Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 5 to 55.