Chapter 5: Configuration
Decoded (Internal) Scanners
Decoded (Internal) – Advanced Options
Aim Duration
This parameter determines the total time the aiming pattern appears before the scanner laser begins sweeping. When you
Laser On Time
The value assigned to this parameter determines how long the laser will remain on when the scan button or trigger is pressed.
5.13.2.2 Decoded (Internal) – Advanced Options
Continuous Scan Mode
Setting this parameter to on keeps the laser on and continuously decoding as long as the scanner button is pressed and held down.
Minimum Cancel Time
The value assigned to this parameter determines the time delay before the scanner is turned off, once the scanner trigger or button is released. This gives the scanner a minimum amount of time to complete its current decode before the scan is cancelled when the user quickly triggers on/off.
Low Power Timeout
To extend laser life, you can select the time the scanner remains active following a success- ful decode. The scanner wakes from low power mode when a bar code is
This is only used if the unit’s Trigger Mode has been changed to Continuous On. If the unit is used in a fixed mount this parameter might be used, but not if the unit is used as a hand- held.
When you
Parameter Scanning
Setting this parameter to on allows the scanner to respond to programming bar codes that can be found in the scanner manual. Scanning these is an alternative way to reprogram some of the scanner features
Psion Teklogix NEO | 137 |