Appendix A: Specifications (AWG710B)
AWG710&AWG710B Arbitrary Waveform Generator User Manual A-11Figure A-3: Enhanced mode
1. Sequence 1
Analog Output
Event Input
Event Input Setup time (1152 clocks)
Waveform 1
Minimum Output
Interval (840 to 896 clocks)
Line No. Waveform Name Wait for Trigger Jump to
n: Waveform1 Off m (Waveform3)
n+1: Waveform2 Off m+1 (Waveform4)
m: Waveform3 Off --
m+1: Waveform4 Off --
Jump Setup time (715 clocks)
Waveform 2 Waveform 3 Waveform 3
Event Input Setup time (1152 clocks)
Jump Setup time (715 clocks)
Event Input
Analog Output
Waveform 1 Waveform 2 Waveform 4 Waveform 4
Minimum Output
Interval (840 to 896 clocks)
1-1.
1-2